NAFFCO showcases in Intersec 2017

NAFFCO, the world’s leading producer and provider of life safety solutions displays at Intersec 2017, the world’s largest and most comprehensive commerce and networking exhibition for the Security and Safety industries.
A main producer and supplier of life security options, NAFFCO, the founding sponsor of Intersec is presenting the most recent products and tendencies in safety and safety specializing in its good technologies and innovations. Intersec 2017 is being held from 22nd to 24th January on the Dubai International Convention and Exhibition Centre, Dubai, UAE.
Recognizing Intersec as a world assembly platform, Eng. Khalid Al Khatib, Chief Executive Officer mentioned, “NAFFCO might be standing out as a “one-stop-solution” source for all types of fireside safety methods. In the 1,439-sqm stand at Hall 6 of the Dubai World Trade Center, NAFFCO will showcase its wide range of state-of-the-art firefighting products together with heavy-duty fire hoses and reels, hearth suppression and protection methods, custom-made hearth cupboards, extinguishers, fire pumps fire-rated doors, fireplace alarms, CCTV techniques, ambulances, rescue vehicles and fire vehicles as properly as mobile hospitals and platform vehicles.”
In this year’s version, NAFFCO highlighted, amongst other improvements and services, the newly launched Pump Cloud, NAFFCO Automatic Fuel Filtration System, Aircraft Rescue Firefighting Vehicle (ARFFV), Emergency Lighting System, NAFFCO Training, New Eco-barid foam extinguisher for lithium batteries – a new sort of specialist fireplace extinguisher to be used on class D fires; SIL2 etc
Pump Cloud:
Considering the essential role of fireplace pump as the center of firefighting system, it ought to be monitored round-the-clock to guarantee that it’s properly working particularly during emergencies. Pump Cloud is a modern and revolutionary system that allows 24/7 monitoring of fire pumps. It uses an interface unit related with the fireplace pump controllers and associated sensors and equipment within the Fire Pump room which in turn will ship monitored alerts to a particular modem that communicates with NAFFCO Desktop Managing system through 3G or GPRS, where NAFFCO maintenance staff on standby are monitoring the pump 24 / 7 and prepared for motion.
NAFFCO Automatic Fuel Filtration System:
Fuel contamination is a significant cause of untimely shutdown for standby engines, generator sets, fireplace pump engines, and different diesel engine assist functions. Contamination starts as soon because the tanks are stuffed and continues until the fuel is used. As the length of storage interval is increased, the chance of premature engine shutdown can be elevated because of clogged filter or extreme water entrainment.
The resolution: NAFFCO Automatic Fuel Filtration System. It is a self-contained, stand-alone system that removes and prevents the build-up of water, sludge and contaminants in tanks. It stabilizes diesel and bio-fuels, eliminates microbial contamination to optimize and keep gas high quality. It is designed to satisfy NFPA necessities in sustaining and cleansing gasoline saved in gasoline tanks in accordance with NFPA 20, NFPA 25, and NFPA a hundred and ten.
Aircraft Rescue Firefighting Vehicle (ARFFV):
Also generally known as the Fire Falcon 6, ARFFV is back within the Intersec this yr proudly showcasing its own manufactured prototype of the falcon cabin which was efficiently examined as per the internationally acknowledged testing E/ECE/324 and E/ECE/TRANS/505, Addendum 28, Regulation No. 29 with regard to safety of the occupants of the cabin. In the continuous effort to offer NAFFCO customers with proven and protected applied sciences, the requirements of the usual were purposely exceeded and the falcon cabin demonstrated glorious strength and influence properties. The roof strength was tested with 13500 kg, which is 3500kg greater than the regulation requirement and the front impact check was carried out at 55 kJ, against the 45 kJ specified by the regulation.
Emergency Lighting System:
When the overall synthetic lighting fails, orientation should nonetheless be ensured in buildings even for guests. Accordingly, there are legal provisions governing the equipment and dimensioning of emergency lighting installations that shall be activated when there isn’t any mains voltage.
NAFFCO Provides the Intelligent Emergency Lighting Solution that ensures the safety and integrity of your emergency system with automated monitoring and reporting solution. All the products Control Panel, Emergency Luminaires and accessories are absolutely tested and authorized by British Standards Institution (BSI).
Deadline & Grouping of Lights, Sets Maintenance Schedule, Generates auto Reports by utilizing NAFFCO Addressable Emergency lighting monitoring contact panel. NAFFCO Emergency and Exit Lights are designed with newest LED technology which is absolutely complying with green building concept.
Eco Barid Foam Fire Extinguisher for Class ABD and F
NAFFCO stored strain type Eco Barid foam extinguisher are multipurpose, ideal for fires involving risky liquids and freely burning material corresponding to paper, fabric, wood, furnishings and cooking oil or fats fires (A,B,D and F courses of fire) and is appropriate for the use with most kinds of proportioning and discharge devices which performs excellently when used with CAF methods. ECO BARID FOAM is 100% environmental pleasant free from PFOA, PFOs and fluorine.
It is designed for rapid fireplace knockdown by creating a movie on the item of fireplace and in addition to this, it creates a cooling effect and acts like a fireplace sealant which helps to extinguish the fireplace faster and minimize re ignition. The environmental pleasant ingredients within the foam focus have the deep impregnation capability when used on combustible strong material fires which makes it close to to unimaginable for re ignition. This is important when extinguishing deep-seated fires in wood, paper, rubber, and different ordinary combustibles. It acts like a fire sealant when utilized on combustible supplies.
SIL2
Safety Integrity Level (SIL2) is a measure of the reliability of a system to be in operation when a maximum risk and fault are analysed based on no of floors, occupancy and in accordance to the guide strains set by the Engineer or the Authority having Jurisdiction to maximise the reliability and efficiency of Life Safety, that’s where you will want a SIL2 rated panel.
Why SIL2 supersedes the Normal Addressable Fire Alarm Panel?
Redundancy: CPU, I/O cards, Power Supply and Display obtainable on the panel to make sure the continuous operation incase of one or more failures.
Hot–swap: CPU, I/O playing cards, Power Supply and Display may be replaced without switching off the panel, thus sustaining system safety and security performance.
Extreme discount of false alarms below acceptable ranges out of a hundred alerts there’s a possibility for just one fault.
High degree of Reliability, Availability and Maintainability (RAM) for the software program and hardware of the system.
High tolerance and stability over electromagnetic noise.
NAFFCO Training
To increase awareness and alleviate technical data on fireplace safety standards, NAFFCO offers training applications based mostly on 3 main facets specifically:
Theory. Using the classroom surroundings our internationally accredited instructors educate NFPA rules and regulations.
Practical. We supply hands-on training on all fire safety methods
Testing and certification. We supply NFPA certifications as properly as NAFFCO certifications
For extra data please go to www.naffco.com
Share

Leave a Comment